Digital symmetrical analysis of AC/DC interactions and harmonic mitigations for multi-pulse converter systems

Research Abstract
This article develops a digital mathematical model in symmetrical components to handle multi-pulse converters power system equipped with correction power factor capacitors or shunt passive harmonic filters. The model simulates AC/DC interaction system in both AC and DC sides with balanced and unbalanced AC system voltages and is adapted for general representation of converter transformers to meet Y/?, Y/Y, and Y/Z connections. Comparison results with previous works are given with correction power factor capacitors or shunt passive harmonic filters. The results also included the interaction of AC/DC systems resonating with shunt capacitors at one or more of harmonic power-frequency and the resulting zero sequence harmonics due to AC unbalanced voltage.
Research Authors
Abdel-Salam, M., Abdel-Sattar, S., Abdallah, A.S., and Ali, H.
Research Department
Research Journal
Journal of Electric Power Components and Systems
Research Member
Research Pages
pp.299-318
Research Rank
1
Research Vol
Vol.35
Research Year
2007

Symmetrical component analysis of multi-pulse converter systems

Research Abstract
This article describes a new method for dynamic simulation of multi-converter systems. This simulation is based on symmetrical components in time domain analysis and general representation of converter transformers to meet Y /?, Y / Y , and Y / Z connections. The simulation is suitable for harmonic analysis of balanced and unbalanced AC voltages. The computed currents and voltages agreed reasonably with those measured and reported in the literature for the characteristic and non-characteristic harmonics.
Research Authors
Abdel-Salam, M., Abdel-Sattar, S., Abdallah, A.S., and Ali, H.
Research Department
Research Journal
Journal of Electric Power Components and Systems
Research Member
Research Pages
pp.867-888
Research Rank
1
Research Vol
Vol.34, No.8
Research Year
2006

Ferroresonance phenomenon in power transformers- experimental assessment

Research Abstract
This paper reports on the results of recent research and development efforts to study and assess various impacts of ferroresonance phenomenon on operating performance of power transformers and to investigate ways to mitigate the effects of such phenomenon. Three-phase core-type transformers are used in the study. The results of the technical investigation and the associated ferroresonance experimental work performed showed that ferroresonance can cause dangerous overvoltages and overcurrents in three-phase coretype transformers. Sensitivity analysis results are also presented to determine the impact of various design and operating parameters on the resulting overvoltages and overcurrents caused by ferroresonance.
Research Authors
Abdallah, A.S. and El-Kady, M.A
Research Department
Research Journal
Journal of King Abdulaziz University
Research Member
Research Rank
1
Research Vol
Vol. 16, No.1
Research Year
2005

Effect of the cross-magnetizing phenomenon on the transient performance of a saturated synchronous machine under three-phase short-circuited

Research Authors
Abdallah, A.S. and Abdel-Sattar, S
Research Department
Research Journal
Journal of Modelling, Measurment and Control, A, AMSE Press
Research Member
Research Pages
pp. 41-54
Research Rank
1
Research Vol
Vol. 53, No. 3
Research Year
1993

Effect of saturation on the steady-state stability of a synchronous machine connected to an infinite bus system

Research Authors
El-Serafi, A.M., Abdallah, A.S
Research Department
Research Journal
IEEE Transactions on Energy Conversion
Research Member
Research Pages
pp. 514-521
Research Rank
1
Research Vol
Vol. EC-6, No.3
Research Year
1991

Experimental study of the saturation and cross- magnetizing phenomenon in saturated synchronous machines

Research Authors
El-Serafi, A.M., Abdallah, A.S.,El-Sherbiney, M.K. and Badawy, E.H
Research Department
Research Journal
IEEE Transactions on Energy Conversion
Research Member
Research Pages
pp. 815-823
Research Rank
1
Research Vol
Vol. EC-3, No.4
Research Year
1988

Experimental verification of the cross-magnetizing phenomenon in saturated synchronous machines

Research Authors
El-Serafi, A.M., Abdallah, A.S.,El-Sherbiney, M.K. and Badawy, E.H
Research Department
Research Journal
IEEE Transactions on magnetics
Research Member
Research Pages
pp.3029-3032
Research Rank
1
Research Vol
Vol. MAG-23, No.5
Research Year
1987