Skip to main content

Prof. Dr. Hassan Mohammed Huwail, Dean of the College, extends his warmest congratulations to Prof. Dr. Abdullah Abdul-Zaher on the occasion of his promotion to the rank of Professor in the Department of Mental Health at the College. Wishing him continued

Prof. Dr. Hassan Mohammed Huwail, Dean of the College, extends his warmest congratulations to Prof. Dr. Abdullah Abdul-Zaher on the occasion of his promotion to the rank of Professor in the Department of Mental Health at the College. Wishing him continued success.

 

 

 

Discussion of the master's thesis in education, specializing in curricula and teaching methods (industrial education), submitted by researcher Muhammad Marahiq Khalif Khalawi, entitled: Using worksheet strategies in teaching the subject of practical studi

Today, Thursday, 2024/8/29, the master's thesis in education, specializing in curricula and teaching methods (industrial education), submitted by researcher Muhammad Marahq Khalif Khalawi, entitled / Using worksheet strategies in teaching the subject of practical studies (electricity) to develop industrial security skills among middle school students in the State of Kuwait, was discussed. The discussion and judgment committee consists of the following professors:

Prof. Dr. / Obada Ahmed Obada Al-Khawli

Professor of Curricula and Teaching Methods of Industrial Education, Full-time - Faculty of Education - Suez University - Chairman and Examiner

Prof. Dr. / Ali Sayed Abdel Jalil

Professor of Curricula and Teaching Methods of Industrial Education, Full-time - Faculty of Education - Assiut University - Member

And Supervisor

Prof. Dr. / Hassan Muhammad Hawil

Professor of Curricula and Teaching Methods of Industrial Education and Dean of the Faculty of Education - Assiut University - Member and Supervisor

Prof. Dr. / Hamdi Muhammad Muhammad Al-Baytar

Professor of Curricula and Teaching Methods of Industrial Education - Faculty of Education - Assiut University - Member and Examiner

 

 

 

Discussion of the master’s thesis in special education, specialization (autism), submitted by researcher Walid Abdel Salam Abdel Aal Salman, entitled: Mental wandering and its relationship to visual-spatial working memory in autistic children with high fu

Today, Thursday, 2024/8/29, the master's thesis in special education (autism) was discussed by researcher Walid Abdel Salam Abdel Aal Salman entitled / Mental wandering and its relationship to visual working memory

spatial in autistic children with high functional performance.

Supervision/

Prof. Dr. Samuel Tamer Bishri

Professor and Head of the Department of Mental Health - Faculty of Education - Assiut University

Dr. Rania Imam Mustafa

Lecturer of Educational Psychology - Faculty of Education, Assiut University

The discussion and judgment committee consisted of the following professors:

Prof. Dr. Samuel Tamer Bishri Professor and Head of the Department of Mental Health - Faculty of Education - Assiut University - Chairman and Supervisor

Prof. Dr. Ahmed Hassan Mohamed Al-Laithi

Professor of Mental Health, Faculty of Education - Helwan University and the Institute of Arab Research and Studies - Member and Discussant

Prof. Dr. Ali Salah Abdel Mohsen

Assistant Professor of Educational Psychology - Faculty of Education - Assiut University

Member and Discussant

 

 

 

 

The Mediating Role of Mindfulness Facets in the Relationship between Depression Symptoms and Obsessional Beliefs among University Students

Research Abstract
Background: The quality assurance of 3D treatment planning system (TPS)will be investigated by different things such as beam configuration, dose calculation and plane evaluation which uses dose volume histogram analyzes. Material and method: the study was performed by XIO TPS (version 4.3.3) available at South Egypt Cancer Institute (SECI). This TPS employs two different 3D algorithms (Clarkson (CLK) and Fast Fourier Transform Convolution (CON)). Relative dose calculation (RDC) in terms of percentage depth dose (PDD) and off axis beam profiles (OAR) and absolute dosecalculation (ADC) in terms of dose and output factor were used and compared with the measured one using ionization chambers with water or solid phantoms in medical linear accelerator linac (Siemens Mevatron MD2).Two photon energies 6MV and 15MV were studied using field sizes of 10×10cm2 and 25×25cm2 for open field. Results: The OAR and PDD are divided into regions each of these having a tolerance limit of the accuracy acceptable. The large point of deviation appeared in field size 25×25cm2 at energy 15MV in outer regionδ4 of OAR. This region recorded the largest deviation than the others regions. In PDD curves haven’t any deviation.Larger deviations were observed with CLK algorithm compared to CON algorithm. 20 points out of criteria were observed in the RDC of a large field size 25×25cm2, while 16 points were out of criteria in the field size 10×10cm2. Conclusion: This work presents a feasibility and performance of quality assurance tasks the TPS for external photon beam
Research Authors
Abdallah Alkholy
Research Date
Research Department
Research Journal
Clinical Schizophrenia & Related Psychoses
Research Pages
1-7
Research Publisher
IOSR
Research Rank
Q2
Research Vol
15
Research Website
Doi: 10.3371/CSRP.AAMA.12.09.21
Research Year
2021

Non-reactivity, Non-judging, Control of Thoughts Beliefs and Acting with Awareness as Predicators of Depression Symptoms among Student Teachers.

Research Abstract
A quarter-wavelength coaxial cavity with a longitudinal radio-frequency power supply was fabricated and tested. The cavity was designed as a pre-buncher for a thermionic triode-type radio-frequency gun of a mid-infrared free electron laser facility. The triode structure was formed to ensure the reduction of the back-bombarding effect, which usually appears in thermionic radio-frequency guns. The coaxial cavity was tested using a tungsten dispenser cathode. From the results of the cold test, a cavity voltage of about 25 kV can be attained, which corresponds to designed characteristics. In contrast, the hot test showed a sudden drop in voltage, resulting in an unstable operation. The small dimensions of the cavity caused some low-field effects, which led to multipactoring. In this paper, we report the tested characteristics of the pre-bunching cavity.
Research Authors
Abdallah Alkholy
Research Date
Research Department
Research Journal
Review of International Geographical Education Online(RIGEO)
Research Pages
1205-1218
Research Publisher
IOP Publishing
Research Rank
Q3
Research Vol
11
Research Website
doi: 10.48047/rigeo.11.07.112
Research Year
2021

Irrational beliefs and thought control strategies as predictors of psychological stress in a sample of kindergarten Section Students at Prince Sattam University.

Research Abstract
A quarter-wavelength coaxial cavity with a longitudinal radio-frequency power supply was fabricated and tested. The cavity was designed as a pre-buncher for a thermionic triode-type radio-frequency gun of a mid-infrared free electron laser facility. The triode structure was formed to ensure the reduction of the back-bombarding effect, which usually appears in thermionic radio-frequency guns. The coaxial cavity was tested using a tungsten dispenser cathode. From the results of the cold test, a cavity voltage of about 25 kV can be attained, which corresponds to designed characteristics. In contrast, the hot test showed a sudden drop in voltage, resulting in an unstable operation. The small dimensions of the cavity caused some low-field effects, which led to multipactoring. In this paper, we report the tested characteristics of the pre-bunching cavity.
Research Authors
Abdallah Alkholy
Research Date
Research Department
Research Journal
Humanities & Social Sciences Reviews
Research Pages
407-421
Research Publisher
IOP Publishing
Research Rank
Q3
Research Vol
7
Research Website
https://doi.org/10.18510/hssr.2020.8440
Research Year
2020

The Saudi Version of the Dula Dangerous Driving Index among University Student drivers

Research Abstract
The common radioactivity substances (Ra-226, Th-232 and K-40) were measured in oil ash samples collected from the Assiut Thermal Power Plant (ATPP) in Egypt by gamma spectrometry. Outcomes were contrasted with those from past investigations. The activity concentrations have declined from past investigations by around 58 %, 77 % and 95 % for 226Ra, 232Th, and 40K, respectively. The reason for this extreme decrease will be discussed. A positive with moderate correlation between 226Ra and 232Th, and between 226Ra and 40K in the examined ash samples was identified from the observed correlation R2 of 0.6 and 0.4 respectively. All estimations of radiological risk indices demonstrate a generous decrease; however, they remain more than the world reference. For instance, the radium equivalent activities (Raeq) and the hazard indices are considerably more than 370 Bq kg-1 and unity, respectively. Mean absorbed dose rate was 3250 nGy h-1, which is around fifty-five times more than the world reference estimation of 59 nGy h-1; relating annual external effective dose is assessed to be at 3.9 mSv y-1, which is around fifty-five times higher than what is found in regions of common foundation radiation 0.07 mSv y-1.
Research Authors
Abdallah Alkholy
Research Date
Research Department
Research File
Paper4.pdf (763.2 KB)
Research Journal
REVIEW OF INTERNATIONAL GEOGRAPHICAL EDUCATION
Research Pages
1124-1133
Research Publisher
Polish Forestry Society
Research Rank
Q3
Research Vol
11
Research Website
doi: 10.48047/rigeo.11.07.106
Research Year
2021

The Big Five Personality Traits and Job Satisfaction: The Mediating Role of General Self-Efficacy among Student Teachers

Research Abstract
The common radioactivity substances (Ra-226, Th-232 and K-40) were measured in oil ash samples collected from the Assiut Thermal Power Plant (ATPP) in Egypt by gamma spectrometry. Outcomes were contrasted with those from past investigations. The activity concentrations have declined from past investigations by around 58 %, 77 % and 95 % for 226Ra, 232Th, and 40K, respectively. The reason for this extreme decrease will be discussed. A positive with moderate correlation between 226Ra and 232Th, and between 226Ra and 40K in the examined ash samples was identified from the observed correlation R2 of 0.6 and 0.4 respectively. All estimations of radiological risk indices demonstrate a generous decrease; however, they remain more than the world reference. For instance, the radium equivalent activities (Raeq) and the hazard indices are considerably more than 370 Bq kg-1 and unity, respectively. Mean absorbed dose rate was 3250 nGy h-1, which is around fifty-five times more than the world reference estimation of 59 nGy h-1; relating annual external effective dose is assessed to be at 3.9 mSv y-1, which is around fifty-five times higher than what is found in regions of common foundation radiation 0.07 mSv y-1.
Research Authors
Abdallah Alkholy
Research Date
Research Department
Research File
Paper6.pdf (311.7 KB)
Research Journal
Information Sciences Letters
Research Pages
1947-1955
Research Publisher
Polish Forestry Society
Research Rank
Q2
Research Vol
12
Research Website
http://dx.doi.org/10.18576/isl/120536
Research Year
2023

Psychometric Properties of the Five-Facet Mindfulness Questionnaire among Egyptian university students

Research Abstract
In this study, the natural radionuclides in soil and sand have been measured by using high purity germanium (HPGe) detector. While, radon exhalation rate has been measured by Alpha GUARD. The data analysis is performed to determine 226Ra, 232Th, and 40K activity concentrations in addition to 222Rn exhalation rate. The values of radium equivalent activity (Raeq), external hazard index (Hex), internal hazard index (Hin), and absorbed dose rate were ranged from 46.46 to 124.16 Bq⋅kg−1, 0.07 to 0.33 Bq⋅kg−1, 0.09 to 0.42 Bq⋅kg−1, and 13.24 to 58.37 nGy⋅h−1 respectively in all samples. The area and mass exhalation rates were increased from 9.16 ± 2.83 to 16.18 ± 2.83 Bq⋅m−2⋅h−1 and 1.8 ± 1.34 to 11.35 ± 0.98 Bq⋅kg−1⋅h−1 respectively.
Research Authors
Abdallah Alkholy
Research Date
Research Department
Research File
Paper5.pdf (430.87 KB)
Research Journal
Eurasian Journal of Educational Research
Research Pages
316-341
Research Publisher
Scientific Research Publishing
Research Rank
Q2
Research Vol
97
Research Website
DOI: 10.14689/ejer.2022.97.18
Research Year
2022

فاعلية برنامج إرشادى قائم على تدخلات الامتنان في تحسين السعادة والرضا عن الحياة لدى طلاب الجامعة

Research Abstract
Determination of the full-energy peak efficiency of a detection system is significant in the activity calculation of the measured radioactive samples. In this work, we present an experimental method to determine the absolute efficiency calibration of a NaI(Tl) detector, considering that a standard source of interest is unavailable and by using the known specific activity of a standard sample measured using a HPGe detector. The efficiency of a gamma-ray spectrometer that consists of a coaxial HPGe detector is calculated using Canberra ISOCS/LabSOCS software and a fabricated calibration source. To validate our method, environmental samples (rock and soil samples) were analyzed on both the detectors. The obtained activity concentrations were checked by means of the IAEA proficiency test procedure. The performance criteria evaluation results were found to be ‘Acceptable’ for all the analytical determinations of all the radionuclides under study, except for the samples with low activity (15 Bq kg−1 and 10 Bq kg−1 for 226Ra and 232Th, respectively). The precision of the low-activity samples was not considered ‘Acceptable’ as the results were slightly inaccurate; in this case, the results were considered as ‘Warning’ because the relative bias (RB) was less than the maximum acceptable bias (MAB).
Research Authors
عبدالله الخولى
Research Date
Research Department
Research Journal
مجلة كلية التربية - جامعة أسيوط
Research Pages
68-1
Research Publisher
Taylor & Frances
Research Rank
7
Research Vol
4
Research Website
https://doi.org/10.21608/mfes.2024.360306
Research Year
2024
Subscribe to