Skip to main content

Studies on soil mycoflora of Wadi Bir-El-Ain, Eastern Desert. Egypt

Research Abstract
NULL
Research Authors
Moubasher, A.H.; S.I.I. Abdel-Hafez & O.M.O. El-Maghraby
Research Journal
Cryptogamie Mycologie
Research Pages
129-144
Research Publisher
NULL
Research Rank
2
Research Vol
6 (2)
Research Website
NULL
Research Year
1985

Comparison of Heating Property of LaB6 and CeB6 by Back Bombardment Effect in Thermionic RF gun

Research Abstract
The heating properties of LaB6 and CeB6 cathodes are investigated against the Back Bombardment (BB) effect in thermionic RF guns by using numerical calculations of the stopping range and the heat power deposited inside the cathode materials. Then, the change in the cathode temperature and the corresponding change in the current density during the 5.5 µs macropulse are determined by solving two differential equations. The simulation results show that the change in the current density during the macropulse for LaB6 was two times higher than that for CeB6; hence, the effect of the BB electrons in CeB6 is less than it is for LaB6
Research Authors
Mahmoud Bakr, R. Kinjo, Y. W. Choi, M. Omer, K. Yoshida, S. Ueda, M. Takasaki, K. Ishida, N. Kimura, T. Sonobe, T. Kii, K. Masuda, and H. Ohgaki
Research Department
Research Journal
Journal of the Korean Physical Society,
Research Pages
pp.3273-3279
Research Publisher
NULL
Research Rank
1
Research Vol
V. 59, N. 5,
Research Website
http://www.kps.or.kr/jkps/abstract_view.asp?articleuid=C5C329D2-00B1-42AE-AF1C-23A0B0636726
Research Year
2011

Applications of the three points analysis method for obtaining the trap parameters and the separation of thermoluminescence glow curve into its components.

Research Abstract
Here, we apply a recently developed technique to separate a composite thermoluminescence (TL) glow curve into its individual components and to evaluate the trap parameters of the individual TL glow peaks. These parameters include the order of kinetics b, the activation energy E (eV) and the frequency factor S (s−1) or the pre-exponential factor S″ (s−1). Recently, a general equation was developed to estimate the order of kinetics b. The characteristic point of this equation is that any set of three data points in a TL glow curve can yield b. Using this characteristic, an improved procedure was suggested to separate a composite glow curve, which includes several overlapping peaks, into its individual components and to obtain the trap parameters of the individual glow peaks. The method was applied here to analyze and determine the trap parameters of the TL glow curve of the promising TL dosimetric material, double potassium yttrium fluoride (K2YF5) doped with praseodymium ions (Pr3+), in response to γ-irradiation.
Research Authors
M.S. Rasheedy, M.A. El-Sherif and M.A. Hefni.
Research Department
Research Journal
Radiation Effects & Defects in Solids
Research Member
Research Pages
12
Research Publisher
Taylor Francis online
Research Rank
1
Research Vol
161
Research Website
http://www.tandfonline.com/doi/abs/10.1080/10420150600879732#.Vs-s1hh9670
Research Year
2006

Applications of the three points analysis method for obtaining the trap parameters and the separation of thermoluminescence glow curve into its components.

Research Abstract
Here, we apply a recently developed technique to separate a composite thermoluminescence (TL) glow curve into its individual components and to evaluate the trap parameters of the individual TL glow peaks. These parameters include the order of kinetics b, the activation energy E (eV) and the frequency factor S (s−1) or the pre-exponential factor S″ (s−1). Recently, a general equation was developed to estimate the order of kinetics b. The characteristic point of this equation is that any set of three data points in a TL glow curve can yield b. Using this characteristic, an improved procedure was suggested to separate a composite glow curve, which includes several overlapping peaks, into its individual components and to obtain the trap parameters of the individual glow peaks. The method was applied here to analyze and determine the trap parameters of the TL glow curve of the promising TL dosimetric material, double potassium yttrium fluoride (K2YF5) doped with praseodymium ions (Pr3+), in response to γ-irradiation.
Research Authors
M.S. Rasheedy, M.A. El-Sherif and M.A. Hefni.
Research Department
Research Journal
Radiation Effects & Defects in Solids
Research Pages
12
Research Publisher
Taylor Francis online
Research Rank
1
Research Vol
161
Research Website
http://www.tandfonline.com/doi/abs/10.1080/10420150600879732#.Vs-s1hh9670
Research Year
2006

Applications of the three points analysis method for obtaining the trap parameters and the separation of thermoluminescence glow curve into its components.

Research Abstract
Here, we apply a recently developed technique to separate a composite thermoluminescence (TL) glow curve into its individual components and to evaluate the trap parameters of the individual TL glow peaks. These parameters include the order of kinetics b, the activation energy E (eV) and the frequency factor S (s−1) or the pre-exponential factor S″ (s−1). Recently, a general equation was developed to estimate the order of kinetics b. The characteristic point of this equation is that any set of three data points in a TL glow curve can yield b. Using this characteristic, an improved procedure was suggested to separate a composite glow curve, which includes several overlapping peaks, into its individual components and to obtain the trap parameters of the individual glow peaks. The method was applied here to analyze and determine the trap parameters of the TL glow curve of the promising TL dosimetric material, double potassium yttrium fluoride (K2YF5) doped with praseodymium ions (Pr3+), in response to γ-irradiation.
Research Authors
M.S. Rasheedy, M.A. El-Sherif and M.A. Hefni.
Research Department
Research Journal
Radiation Effects & Defects in Solids
Research Member
Mahmoud Ahmed Hefni Hassan
Research Pages
12
Research Publisher
Taylor Francis online
Research Rank
1
Research Vol
161
Research Website
http://www.tandfonline.com/doi/abs/10.1080/10420150600879732#.Vs-s1hh9670
Research Year
2006

Determination of the trapping parameters of thermoluminescent glow peaks of K2YF5:Ce by three points method

Research Abstract
The three points analysis method was applied to determine the number of peaks and kinetic parameters. These are the order of kinetics b, the activation energy E (eV), the frequency factor S (s−1) or the pre-exponential factor S″ (s−1) and the relative value of the initial concentration of trapped electrons n0 (cm−3) associated with the thermoluminescence (TL) glow peaks in double potassium yttrium fluoride (K2YF5) doped with cerium ions (Ce3+) in response to β-irradiation. The three points analysis method indicated that the glow curve of this material is the superposition of five general-order components, which was referred to as P1–P5, in the temperature range between room temperature and 500 °C.
Research Authors
M.S. Rasheedy, M.A. El-Sherif and M.A. Hefni.
Research Department
Research Journal
Nuclear Instruments and Methods in Physics Research B
Research Member
Mahmoud Ahmed Hefni Hassan
Research Pages
5
Research Publisher
NULL
Research Rank
1
Research Vol
B 258
Research Website
http://www.sciencedirect.com/science/article/pii/S0168583X07005198
Research Year
2007

Determination of the trapping parameters of thermoluminescent glow peaks of K2YF5:Ce by three points method

Research Abstract
The three points analysis method was applied to determine the number of peaks and kinetic parameters. These are the order of kinetics b, the activation energy E (eV), the frequency factor S (s−1) or the pre-exponential factor S″ (s−1) and the relative value of the initial concentration of trapped electrons n0 (cm−3) associated with the thermoluminescence (TL) glow peaks in double potassium yttrium fluoride (K2YF5) doped with cerium ions (Ce3+) in response to β-irradiation. The three points analysis method indicated that the glow curve of this material is the superposition of five general-order components, which was referred to as P1–P5, in the temperature range between room temperature and 500 °C.
Research Authors
M.S. Rasheedy, M.A. El-Sherif and M.A. Hefni.
Research Department
Research Journal
Nuclear Instruments and Methods in Physics Research B
Research Member
Research Pages
5
Research Publisher
NULL
Research Rank
1
Research Vol
B 258
Research Website
http://www.sciencedirect.com/science/article/pii/S0168583X07005198
Research Year
2007

Determination of the trapping parameters of thermoluminescent glow peaks of K2YF5:Ce by three points method

Research Abstract
The three points analysis method was applied to determine the number of peaks and kinetic parameters. These are the order of kinetics b, the activation energy E (eV), the frequency factor S (s−1) or the pre-exponential factor S″ (s−1) and the relative value of the initial concentration of trapped electrons n0 (cm−3) associated with the thermoluminescence (TL) glow peaks in double potassium yttrium fluoride (K2YF5) doped with cerium ions (Ce3+) in response to β-irradiation. The three points analysis method indicated that the glow curve of this material is the superposition of five general-order components, which was referred to as P1–P5, in the temperature range between room temperature and 500 °C.
Research Authors
M.S. Rasheedy, M.A. El-Sherif and M.A. Hefni.
Research Department
Research Journal
Nuclear Instruments and Methods in Physics Research B
Research Pages
5
Research Publisher
NULL
Research Rank
1
Research Vol
B 258
Research Website
http://www.sciencedirect.com/science/article/pii/S0168583X07005198
Research Year
2007

Theoretical studies on the physical and environmental factors which govern the thermal fading of thermoluminescence signal

Research Abstract
Thermoluminescence solid-state detector is widely used to determine the dose in personnel and environmental monitoring for radiation protection purposes, for instance in the field of nuclear power production, medicine and research. However, thermal fading is a limiting factor for a long-term application, especially where temperature is changing significantly during the accumulation period. This paper studied the influence of temperature and duration of storage after irradiation on the thermal fading of the TL signal. Also, this paper discussed the dependence of the thermal fading on the trap parameters of TL glow peak. The most important parameters, which were considered here include the order of kinetics b, the depth of the trap level E (eV) and the frequency factor S (s-1). The dependence of the thermal fading on thermal stability parameters, namely trap depths and frequency factors for the glow peaks is discussed. The variation of the thermal fading as a function of the order of kinetics is demonstrated. In addition, this paper discussed the dependence of the thermal fading on the absorbed dose in case of first-, second- and general-order kinetics. The above-mentioned studies were arranged considering the models of first-, second- and general-order of kinetics
Research Authors
M.S. Rasheedy, M.A. El-Sherif and M.A. Hefni.
Research Department
Research Journal
Proceedings of the Second All African IRPA Regional Radiation Protection Congress
Research Member
Mahmoud Ahmed Hefni Hassan
Research Pages
5
Research Publisher
NULL
Research Rank
3
Research Vol
NULL
Research Website
https://inis.iaea.org/search/search.aspx?orig_q=RN:39086463
Research Year
2007
Subscribe to