Skip to main content

Renewable Pencil Electrodes for Highly Sensitive Anodic
Stripping Voltammetric Determination of 3-Hydroxyflavone and
Morin in Bulk Form and in Biological Fluids

Research Abstract
An electrochemical anodic adsorptive stripping procedure for ultra-trace assay of 3-hydroxyflavone (3HF) and Morin at a renewable pencil electrode (PGE) in bulk form and in biological fluids is described. The nature of the oxidation process of 3HF and Morin taking place at the PGE was characterized by cyclic voltammetry. The results show that the determination of the oxidation peak current is the basis of a simple, accurate and rapid method for quantification of 3HF by square-wave anodic stripping voltammetry. Determination of Morin was achieved by square-wave anodic adsorptive stripping voltammetry of the formed MorinCu(II) complex at a PGE. Factors influencing the trace measurements of 3HF and the MorinCu (II) complex at a PGE are assessed. The limits of detection and quantitation for the determination of 3HF and Morin in bulk form and in biological fluids were determined. The statistical analysis and the calibration curve data for trace determination of 3HF and Morin are reported.
Research Authors
Yassein M. Temerk, Mohamed S. Ibrahim, Mohammed Kotb, Wolfgang Schuhmann
Research Department
Research Journal
Electroanalysis
Research Pages
PP. 1381 – 1387
Research Rank
1
Research Vol
Vol.25, No.6
Research Year
2013

Renewable Pencil Electrodes for Highly Sensitive Anodic
Stripping Voltammetric Determination of 3-Hydroxyflavone and
Morin in Bulk Form and in Biological Fluids

Research Abstract
An electrochemical anodic adsorptive stripping procedure for ultra-trace assay of 3-hydroxyflavone (3HF) and Morin at a renewable pencil electrode (PGE) in bulk form and in biological fluids is described. The nature of the oxidation process of 3HF and Morin taking place at the PGE was characterized by cyclic voltammetry. The results show that the determination of the oxidation peak current is the basis of a simple, accurate and rapid method for quantification of 3HF by square-wave anodic stripping voltammetry. Determination of Morin was achieved by square-wave anodic adsorptive stripping voltammetry of the formed MorinCu(II) complex at a PGE. Factors influencing the trace measurements of 3HF and the MorinCu (II) complex at a PGE are assessed. The limits of detection and quantitation for the determination of 3HF and Morin in bulk form and in biological fluids were determined. The statistical analysis and the calibration curve data for trace determination of 3HF and Morin are reported.
Research Authors
Yassein M. Temerk, Mohamed S. Ibrahim, Mohammed Kotb, Wolfgang Schuhmann
Research Department
Research Journal
Electroanalysis
Research Pages
PP. 1381 – 1387
Research Rank
1
Research Vol
Vol.25, No.6
Research Year
2013

Crystal growth kinetics in Se87.5 Te10 Sn2.5 glass

Research Abstract
The crystallization process of Se87.5 Te10 Sn2.5 glassy was studied by differential thermal analysis (DTA) technique under non-isothermal condition at various heating rates. The crystallization parameters were calculated using different models. The validity of the Johnson–Mehl–Avrami (JMA) model to describe the crystallization process for the studied composition was discussed. Results obtained by directly fitting the experimental DTA data to the calculated DTA curves indicate that the crystallization process of Se87.5 Te10 Sn2.5 glass cannot be satisfactorily described by the JMA model. On the other hand, kinetic parameters of both the peak crystallization temperature Tp and the glass transition temperature Tg are significantly influenced by the heating rate. Simulation results indicate that the Sestak–Berggren (SB) model is more suitable to describe the crystallization kinetics. The crystalline phases were identified by using X-ray diffraction technique (XRD) and scanning electron microscopy (SEM).
Research Authors
M.A. Abdel-Rahim, A. Gaber, A.A. Abu-Sehly, N.M. Abdelazim
Research Department
Research Journal
Journal of Non-Crystalline Solids
Research Pages
PP.158–164
Research Rank
1
Research Vol
Vol.376
Research Year
2013

Effect of the Anodization Parameters on the Volume Expansion of Anodized Aluminum Films

Research Abstract
The effect of anodization parameters, e.g. anodizing voltage, anodizing current, duration time, electrolyte temperature, electrolyte type and concentration, on the volume expansion of anodized Al, Al-1wt%Si and Al-1%Cu thin films have been studied. The volume expansion factor of anodic porous alumina is found to vary from 1.32 to 2.08, depending on the anodizing voltage, anodizing current density and electrolyte type. The electrolyte temperature and impurity type have slight effect on the volume expansion factor. The relation between the pore density of porous alumina and the anodizing voltage is found to follow the relation NP=9.4×1010exp(-0.042V). In addition, the current efficiency during the anodization was determined to be about 83%.
Research Authors
Alaa M. Abd-Elnaiem, A.M. Mebed, A. Gaber, M.A. Abdel-Rahim
Research Department
Research Journal
International Journal of Electrochemical Science
Research Member
Research Pages
PP.10515 - 10525
Research Rank
1
Research Vol
8
Research Website
http://www.electrochemsci.org/papers/vol8/80810515.pdf
Research Year
2013
Subscribe to