Flexible Load Control and Feasible Region Characterization for Distribution Network Operation under Physiology Constraints in Aquaculture

Research Abstract

The rapid deployment of electric equipment in modern aquaculture has made fish-farming facilities a notable source of adjustable demand in agricultural power systems. This study develops a biologically constrained load representation for aquaculture energy systems by embedding dissolved oxygen dynamics, ammonia nitrogen variation, and fish-growth requirements into the power-demand model. The interactions among equipment power, water-environment states, and fish development are described using time-accumulated constraints, from which the admissible operating range of controllable loads is derived. The results indicate that the proposed model can reproduce aquaculture load behavior and support joint scheduling of fishery operation and distribution-network management without violating biological safety requirements. In the tested scenario, the proposed strategy lowers daily fishery electricity use by 641.97 kWh, reduces carbon emissions by 379.24 kg, and decreases daily grid losses by 23.02 kWh, showing its applicability to grid-oriented aquaculture energy management.

Research Authors
Xueqian Fu, Bohao Zeng, Daoliang Li, Mazen Abdel-Salam, Hongbin Sun, Youmin Zhang, Hadeer Hassan El-Hawary
Research Date
Research Department
Research Journal
IEEE Transactions on Smart Grid
Research Website
https://ieeexplore.ieee.org/abstract/document/11775951
Research Year
2026