تجاوز إلى المحتوى الرئيسي

Effect of the cross-magnetizing phenomenon on the transient performance of a saturated synchronous machine under three-phase short circuited

ملخص البحث
In this investigation, a mathematical model for saturated synchronous machines including the effects of both the crossmagnetizing phenomenon and the saturation factors has been used. The effects of the omission of the cross-magnetizing phenomenon from this model on the transient characteristic curves of a saturated synchronous machine under a three-phase short circuit such as the armature, field and damper winding currents, the flux linkages, the electromagnetic torque and the load angle curves, are shown.
مؤلف البحث
AS Abdallah, S Abdel-Sattar
مجلة البحث
Journal: Modelling, Measurement & Control A, vol.53, no.3, p.41-54, 1993.
مؤلف البحث
صفحات البحث
41-54
الناشر
AMSE PRESS
تصنيف البحث
1
عدد البحث
53
موقع البحث
NULL
سنة البحث
1993