Skip to main content

The immobilization of animal cells using the cysteine-modified RGD oligopeptide

Research Authors
Cheol-Heon Yea, Bumhwan Lee, Hyunhee Kim, Sang-Uk Kim, Waleed Ahmed El-Said, Junhong Minc, Byung-Keun Oh and Jeong-Woo Choi.
Research Department
Research Journal
Ultramicroscopy
Research Member
Research Pages
PP.1144– 1147
Research Rank
1
Research Vol
Vol.108
Research Year
2008

Analysis of Intracellular State Based on Controlled 3D Nanostructures Mediated Surface Enhanced Raman Scattering

Research Abstract
Near-infrared surface-enhanced Raman spectroscopy (SERS) is a powerful technique for analyzing the chemical composition within a single living cell at unprecedented resolution. However, current SERS methods employing uncontrollable colloidal metal particles or non-uniformly distributed metal particles on a substrate as SERS-active sites show relatively low reliability and reproducibility. Here, we report a highly-ordered SERS-active surface that is provided by a gold nano-dots array based on thermal evaporation of gold onto an ITO surface through a nanoporous alumina mask. This new combined technique showed a broader distribution of hot spots and a higher signal-to-noise ratio than current SERS techniques due to the highly reproducible and uniform geometrical structures over a large area. This SERS-active surface was applied as cell culture system to study living cells in situ within their culture environment without any external preparation processes. We applied this newly developed method to cell-based research to differentiate cell lines, cells at different cell cycle stages, and live/dead cells. The enhanced Raman signals achieved from each cell, which represent the changes in biochemical compositions, enabled differentiation of each state and the conditions of the cells. This SERS technique employing a tightly controlled nanostructure array can potentially be applied to single cell analysis, early cancer diagnosis and cell physiology research.
Research Authors
Waleed Ahmed El-Said, Tae-Hyung Kim, Hyuncheol Kim, Jeong-Woo Choi
Research Department
Research Journal
plosone Open Access Freely available online
Research Member
Research Rank
1
Research Year
2010

Analysis of effect of nanoporous alumina substrate coated with polypyrrole nanowire on cell morphology based on AFM topography

Research Abstract
In this study, in situ electrochemical synthesis of polypyrrole nanowires with nanoporous alumina template was described. The formation of highly ordered porous alumina substrate was demonstrated with Atomic Force Microscopy (AFM) and Scanning Electron Microscopy (SEM). In addition, Fourier transform infrared analysis confirmed that polypyrrole (PP) nanowires were synthesized by direct electrochemical oxidation of pyrrole. HeLa cancer cells and HMCF normal cells were immobilized on the polypyrrole nanowires/nanoporous alumina substrates to determine the effects of the substrate on the cell morphology, adhesion and proliferation as well as the biocompatibility of the substrate. Cell adhesion and proliferation were characterized using a standard MTT assay. The effects of the polypyrrole nanowires/nanoporous alumina substrate on the cell morphology were studied by AFM. The nanoporous alumina coated with polypyrrole nanowires was found to exhibit better cell adhesion and proliferation than polystyrene petridish, aluminum foil, 1st anodized and uncoated 2nd anodized alumina substrate. This study showed the potential of the polypyrrole nanowires/nanoporous alumina substrate as biocompatibility electroactive polymer substrate for both healthy and cancer cell cultures applications.
Research Authors
Waleed Ahmed El-Said, Cheol-Heon Yea, Mi Jung, Hyuncheol Kim and Jeong-Woo Choi
Research Department
Research Journal
Ultramicroscopy
Research Member
Research Pages
PP.676-681
Research Rank
1
Research Vol
Vol. 110, Issue. 6,
Research Year
2010

3-D nanoporous gold thin film for the simultaneous electrochemical determination of dopamine and ascorbic acid

Research Abstract
In this study, we demonstrated a novel fabrication method of three dimensional nanoporous gold thin film (NPGF) onto gold (Au) substrate using electrochemical deposition method. Scanning electron microscope (SEM) investigation reveals the formation of highly-ordered pores, approximately 30 nm in diameter and 150 nm thick. The NPGF-modified electrode shows a linear range (0.1–40 μM) for dopamine detection in the presence of ascorbic acid. The electrochemical measurements of mixtures of dopamine, ascorbic acid, and uric acid in human serum sample for real sample applications was also investigated based on differential pulse voltammetry (DPV) technique. These high sensitivity and selectivity features of the proposed NPGF biosensor offer great promise for real sample biosensor application.
Research Authors
Waleed Ahmed El-Said, Jin-Ho Lee, Byung-Keun Oh and Jeong-Woo Choi
Research Department
Research Journal
Electrochemistry Communications
Research Member
Research Pages
PP.1756-1759
Research Rank
1
Research Vol
Vol. 12, Issue. 12,
Research Year
2010

Cell-based chip for the detection of anticancer effect on HeLa cells using cyclic voltammetry

Research Abstract
HeLa cells directly immobilized on gold-patterned silicon substrate were used to assess the biological toxicity of anticancer drugs (hydroxyurea and cyclophosphamide). Immobilization of HeLa cells was confirmed by optical microscopy, and cell growth, viability and drug-related toxicity were examined by cyclic voltammetry and potentiometric stripping analysis. The voltammetric behaviors of HeLa cells displayed a quasi-reversible pattern with the peak current exhibiting a linear relationship with cell number. The attached living cells were exposed to different concentrations of hydroxyurea and cyclophosphamide as anticancer drugs, which induced the change of cyclic voltammetry current peak. As the exposed concentration of anticancer drugs was increased, the change of current peak was increased, which indicates the decrease of cell viability. Trypan Blue dyeing was performed to confirm the results of the effect of anticancer drugs on the cell viability which was obtained from cyclic voltammetry assay. The proposed direct cell immobilization method technique can be applied to the fabrication of cell chip for diagnosis, drug detection, and on-site monitoring.
Research Authors
Waleed Ahmed El-Said, Cheol-Heon Yea, Hyunhee Kim, Byung-Keun Oh and Jeong-Woo Choi
Research Department
Research Journal
Biosensors and Bioelectronics
Research Member
Research Pages
PP.1259-1265
Research Rank
1
Research Vol
Vol. 24, Issue. 5,
Research Year
2009

Detection of effect of chemotherapeutic agents to cancer cells on gold nanoflower patterned substrate using surface-enhanced Raman scattering and cyclic voltammetry

Research Abstract
In vitro assays have generally been carried out for cytological diagnosis and for evaluation of the cytotoxic effect of chemotherapeutic agents as an alternative to animal experiments. In this study, a method for fabrication and application of a gold nanoflower array on an ITO substrate for evaluation of the effect of chemotherapeutic agents on cancer cell behavior by the surface-enhanced Raman scattering (SERS) analysis, as well as the electrochemical detection was described. Due to the increased sensitivity provided by gold nanoflower substrates, the effect of chemotherapeutic agents at low concentration level was successfully detected based on SERS technique. This substrate was found to give enhanced Raman spectra with high surface plasmon field in the near infrared (NIR) spectral range, which minimize fluorescence interference and photo-toxicity. Cyclic voltammetry (CV) was further performed for confirmation of results obtained by SERS assay and showed increased intensity of current peaks for various concentrations at low levels. The developed Au nanoflowers modified ITO substrates developed in this study could be used as a simultaneous SERS and CV substrate to determine the effects of chemotherapeutic agents on cancer cells.
Research Authors
Waleed Ahmed El-Said, Tae-Hyung Kim, Hyuncheol Kim, b and Jeong-Woo Choia
Research Department
Research Journal
Biosensors and Bioelectronics
Research Member
Research Pages
PP.1486-1492
Research Rank
1
Research Vol
Vol. 26, Issue. 4,
Research Year
2010

Three-dimensional mesoporous gold film to enhance the sensitivity of electrochemical detection

Research Abstract
Cell–cell and cell–extracellular matrix (ECM) adhesion are fundamental and important in the development of a cell-based chip. In this study, a novel, simple, rapid, and one-step technique was developed for the fabrication of a uniform three-dimensional mesoporous gold thin film (MPGF) onto a gold (Au) coated glass plate based on an electrochemical deposition method. Scanning electron microscopy images demonstrated that the resulting MPGF electrode had uniformly distributed pores with diameters of about 20 nm. The cyclic voltammetric behavior of [Fe(CN)6]4 − /3 − coupled onto MPGF and Au electrodes demonstrated that the MPGF electrode had a higher electrocatalytic sensitivity and reversibility than the bare Au electrode. The Arg–Gly–Asp (RGD) sequence containing the peptide was immobilized on the MPGF and bare Au substrates. HeLa cancer cells were then cultured on the RGD peptide layer. The successful immobilization of the peptide and cells was confirmed by atomic force microscopy. The cell proliferation and viability were evaluated by cyclic voltammetry and Trypan blue dyeing assay. These results indicated that the RGD/MPGF modified electrodes showed an electrochemical sensitivity in the detection of cancer cells which is approximately three times higher, especially at low cell density, than RGD/Au electrodes. This much improved sensitivity of the MPGF modified electrode demonstrates the potential for the fabrication of a highly sensitive and low-cost cell-based chip for rapid cancer detection.
Research Authors
Waleed Ahmed El-Said, Tae-Hyung Kim, Hyuncheol Kim and Jeong-Woo Choi
Research Department
Research Journal
Nanotechnology
Research Member
Research Rank
1
Research Vol
Vol. 21, No. 45
Research Year
2010

Effects of Hall and ion-slip currents on free convective heat transfer
flow past a vertical plate considering slip conditions

Research Abstract
A similarity solution is presented for the heat transfer flow considering slip conditions along with hall and ion-slip currents. The governing partial differential equations are reduced to a system of ordinary differential equations and then solved numerically by the method of Nachtsheim-Swigert shooting iteration technique based of Runge-Kutta sixth order iteration scheme. Results for the non dimensional velocity and temperature profiles are shown graphically for a range of values of the problem parameter. The profiles for shear stress due to primary and secondary velocity and temperature gradient are also studied.
Research Authors
M. Ferdows, Esrat Jahan, M.A.A. Hamad, Masahiro OTA
Research Department
Research Journal
Canadian Journal on Science and Engineering Mathematics
Research Member
Mohammed Abdallah Abdallah Hamad
Research Pages
70-76
Research Publisher
A M Publisher
Research Rank
1
Research Vol
Vol 2 - No 2
Research Year
2011
Subscribe to