تجاوز إلى المحتوى الرئيسي

Onset Voltage of Corona in Conductor-to-Plane Gaps as Influenced by
Underneath Grounded and Negatively-Stressed Metallic Grids
(Theory versus Experiment)

ملخص البحث

This paper evaluates the influence on the positive DC corona onset voltage in conductor-to-plane gaps of a grid of metallic wires placed underneath and parallel to the stressed conductor. A systematic experimental study investigates the dependency of the onset voltage on the gap geometry and the particulars of grounded and negatively stressed grids. These particulars include the wire-to-wire spacing, number, lateral distribution and height of grid wires. It was found that the number and distribution of grid wires are the major factors that influence the corona onset voltage together with the radius of the stressed conductor. In a theoretical approach, calculated values for the onset voltage of positive corona as influenced by the grid particulars are obtained using a method based on the criterion of onset streamers self-sustained growth. This calls for calculating the electric field in the vicinity of the stressed conductor in the presence of the grid. A comparison is made between the calculated onset voltages and those measured experimentally.

مؤلف البحث
M. Abdel-Salam, A. Hashem, A. Turky and A. Abdel Aziz
قسم البحث
مجلة البحث
International Journal of Plasma Environmental Science & Technology
مؤلف البحث
صفحات البحث
151-158
تصنيف البحث
1
عدد البحث
Vol. 1, No. 2
موقع البحث
http://www.iesj.org/html/service/ijpest/ijpest_vol6_no1_2012.html
سنة البحث
2007