تجاوز إلى المحتوى الرئيسي

Failed intramedullary nailing of femur: open reduction
and plate augmentation with the nail in situ

ملخص البحث
Methods Fourteen patients with aseptic fractures that failed to unite after intramedullary nailing (IMN) of the femur were treated by augmentation of fixation by dynamic compression plate (DCP) with the nail in situ. In six of them that had axial or rotational malalignment, direct reduction of the bone fragments and plating were done. Iliac bone grafting was performed in nine cases, when there were gaps between the fragments and in atrophic nonunions. Patients were followed-up for an average of 26 months. Results All patients had radiological union in an average of 4.3 months with an improvement in alignment, range of motion and shortening. Conclusions For failed IMN of the femur, augmentation of fixation by compression plate, with the nail in situ, is a good line of treatment. In cases with malalignment, correction was possible followed by plate augmentation
مؤلف البحث
Galal Zaki Said & Hatem G. Said & Mohammad M. El-Sharkawi
مجلة البحث
International Orthopaedics (SICOT)
مؤلف البحث
صفحات البحث
PP.1089–1092
الناشر
NULL
تصنيف البحث
1
عدد البحث
Vol.35
موقع البحث
DOI 10.1007/s00264-010-1192-4
سنة البحث
2011