تجاوز إلى المحتوى الرئيسي

Potential Profile Measurements Inside a Gridded Cathode at High Potential in a Spherical Inertial Electrostatic Confinement Device

ملخص البحث

This paper proposes a Langmuir probe–based diagnostics for plasma parameters inside gridded cathodes at high bias potentials in inertial electrostatic confinement devices. As the first step for the proof of concept, floating potential profiles were measured in deuterium and helium plasmas in a glow-discharge mode. The measurements with fusion-relevant cathode voltages up to 55 kV were carried out successfully. The results revealed that the positive potential buildup at the center ranges from 5% to 8% of the applied bias voltage to the gridded cathode, which is found to be much smaller than those in earlier works under cathode voltages lower than 5 kV. It was also shown that the floating potential profile is different significantly between deuterium and helium discharge plasmas.

مؤلف البحث
Kai Masuda, Ryosuke Kashima & Mahmoud A. Bakr
قسم البحث
مجلة البحث
Fusion Science and Technology
مؤلف البحث
صفحات البحث
1-6
الناشر
Taylor and francis
تصنيف البحث
1
عدد البحث
NULL
موقع البحث
https://doi.org/10.1080/15361055.2019.1610292
سنة البحث
2019