Skip to main content

Energy and exergy assessment of new designed solar air heater of V-shaped transverse finned absorber at single- and double-pass flow conditions

Research Abstract

Flat plate solar collector is one of the main solar collectors that has a simple structure, reliable operation, large heat preoccupation area, and low cost. Its drawback is the low heat transfer between the working air and the absorber plate. A solar air heater of V-shaped transverse finned absorber having new designed absorber plate of lateral gaps and central holes to enhance its performance is investigated experimentally at single-pass and double-pass airflow conditions. Moreover, the energy and exergy assessment of its performance was studied and compared with traditional longitudinal finned heater having the same fin surface area and construction except for the absorber plate design. The study is investigated at air mass flow rates of 0.025, 0.05, and 0.075 kg/s. Findings show that the new heater achieves maximum outlet temperature rising of 28.2 °C at 0.025 kg/s and double-pass flow. Moreover, it has an average daily energy efficiency of 88.5%, 81.88%, and 61.3% at mass flow rates of 0.075, 0.05, and 0.025 kg/s with increments of 9.4%, 13.3%, and 9.66%, respectively, compared to the longitudinal finned heater. Additionally, it achieves exergy efficiencies of 2.5%, 2.1%, and 1.7% at mass flow rates of 0.025, 0.05, and 0.075 kg/s with increments 18%, 25.7%, and 18.2%, respectively, relative to longitudinal finned heater. Furthermore, the new heater design possesses greater energy efficiency comparing to former studied SAH designs.

Research Authors
Saleh Abo-elfadl Ahmed Abd Elrasheed, Hamdy Abo Ali Hassan Ibrahim, Mohammed Fekry Farah El-Dosoky
Research Date
Research Journal
Environmental Science and Pollution Research
Research Pages
1-19
Research Publisher
Springer
Research Website
https://link.springer.com/article/10.1007/s11356-021-15163-z
Research Year
2021

Energy, exergy, and enviroeconomic assessment of double and single pass solar air heaters having a new design absorber

Research Abstract

This paper experimentally examines the performance of solar air heater (SAH) having a newly designed tubular absorber comprising adjacent parallel tubes called tubular SAH (T_SAH) via energy, exergy, and enviroeconomic standpoints. A comparative performance assessment between T_SAH and flat plate solar air heater (F_SAH) at diverse air mass flow rates (MFRs) of 0.075, 0.05, and 0.025 kg/s is performed. Experiments for both heaters are tested using two flow pass arrangements of single-pass (SP) and double-pass (DP). The results reveal that maximum enhancement in thermal and exergy efficiencies of 133 % and 330 %, respectively is obtained when using SP T_SAH against SP F_SAH at air MFR of 0.025 kg/s. It is found that when there is an increase in air MFR, there is a significant increment in thermal efficiency, whereas there is a reduction in exergy efficiency. Despite the performance in the case of T_SAH is more effective than F_SAH, the enhancement in the case of DP F_SAH due to using DP flow configuration is greater than that of DP T_SAH. Finally, the results indicate that the carbon credit earned regarding the amount CO2 mitigated for SP F_SAH and SP T_SAH at MFR of 0.075 kg/s is estimated at 391.6 $/year and 561.9 $/year, respectively.

Research Authors
Saleh Abo-elfadl Ahmed Abd Elrasheed,Mohamed S. Yousef, Hamdy Abo Ali Hassan Ibrahim
Research Date
Research Journal
Process Safety and Environmental Protection
Research Pages
451-464
Research Publisher
Elsevier
Research Vol
149
Research Website
https://www.sciencedirect.com/science/article/abs/pii/S0957582020318796
Research Year
2021

Investigation experimentally the impact of condensation rate on solar still performance at different thermal energy storages

Research Abstract

In this paper, an experimental investigation is performed on the impact of condensation rate of solar still condenser at different thermal energy storage materials on the performance of single slope passive solar still. The condensation rate is changed by installing different designs of the still condenser: (i) glass plate condenser, GC, (ii) corrugated aluminum sheet heat sink condenser, CHS, (iii) aluminum heat sink condenser having vertical rectangular fins at its outer surfaces RHS, (iv) aluminum heat sink condenser having pin fins at its outer surface, PHS, (v) aluminum heat sink condenser having pin fins at its outer and inner surfaces, DPHS. Two different thermal energy storage materials inside the still basin are used; sand and black wool fibers (BWF) plus pure saline water which yield different evaporation rates of the saline water. The findings show that increasing the heat transfer rate (HTR) by the condenser increases the still yield to a limit and then decreases this yield at higher rates. Moreover, increasing the evaporation rate by using thermal energy storage material reduces the negative impact of high condensation rate. The still yield of GC is the minimum while the still yield in case of PHS has the maximum production. Solar still with PHS condenser achieves maximum yield increments of 54%, 63%, 76% in case of saline water only, sand, and BWF medium in the basin, respectively compared to the case of GC condenser with saline water only (conventional still) in the basin. The conventional still has the minimum efficiency of 23.3% and the still with PHS condenser and BWF achieves the maximum still efficiencies of 40.7%. Moreover, enhancement of HTR through using of DPHS condenser reduces the still efficiency to 29.2%, 34.3%, and 37.5% in case of pure saline water, sand, and BWF, respectively. Using PHS condenser with BWF in the still basin reduces the freshwater yield cost by about 21% compared to conventional still.

Research Authors
Saleh Abo-elfadl Ahmed Abd Elrasheed, Hamdy Abo Ali Hassan Ibrahim
Research Date
Research Journal
Journal of Energy Storage
Research Pages
12014
Research Publisher
Elsevier
Research Vol
34
Research Website
https://www.sciencedirect.com/science/article/abs/pii/S2352152X20318491
Research Year
2021

Assessment of double-pass pin finned solar air heater at different air mass ratios via energy, exergy, economic, and environmental (4E) approaches

Research Abstract

In this study, an assessment based on energy, exergy, economic, and environmental approaches on a double-pass (DP) solar air heater (SAH) having pin finned absorber at different air mass ratios up and down the absorber is investigated experimentally. Four air mass ratios are considered: (i) all the air mass flow passes up the absorber and returns to pass down the absorber (DP), (ii) 2/3 of the airflow passes up the absorber and returns to mix with the remainder of air to pass down the absorber (2/3 DP), (iii) the same as (ii) but 1/3 of the air passes up the absorber (1/3 DP), and (iv) all the air mass passes only down the absorber (single pass, SP). For all mass ratios, the performance of pin finned SAH (P_SAH) is compared with that of flat SAH (F_SAH). The results indicated that the air temperature rise and energy and exergy efficiencies of P_SAH are highly greater than those of F_SAH. The highest average thermal efficiency of F_SAH is 56.7% obtained at DP flow condition, whereas the highest value of P_SAH is 65.21% obtained at 2/3 DP with an increase of 17.6% compared with F_SAH. Also, P_SAH has higher average exergy efficiency of about 34.7% compared to F_SAH. Furthermore, P_SAH achieves energy payback time (EPBT) lower than that of F_SAH, while P_SAH has higher embodied energy. The findings indicated that F_SAH at SP airflow pattern has the maximum energy cost (0.0427 $/kWh), whereas P_SAH at 2/3 DP airflow pattern achieves the minimum energy cost (0.037 $/kWh). Finally, the proposed P_SAH system appears to be more viable from exergoeconomic and enviroeconomic approaches compared to F_SAH.

Research Authors
Saleh Abo-elfadl Ahmed Abd Elrasheed,Mohamed S. Yousef, Hamdy Abo Ali Hassan Ibrahim
Research Date
Research Journal
Environmental Science and Pollution Research volume
Research Pages
13776–13789
Research Publisher
Springer
Research Vol
28
Research Website
https://link.springer.com/article/10.1007/s11356-020-11628-9#Sec5
Research Year
2021

Energy and exergy assessment of integrating reflectors on thermal energy storage of evacuated tube solar collector-heat pipe system

Research Abstract

An experimental study is presented on the energy and exergy assessment of integrating reflectors with an evacuated tube solar collector-heat pipe (ETSC-HP) system on its thermal energy storage. The impact of using upper, lower, and upper and lower (two) reflectors on the thermal energy storage, input energy, and energy losses, reflectors' effectiveness, and energy and exergy efficiencies is assessed. A complete thermal model that evaluates the thermal performance of the collector-heat pipe system and selects the reflectors title angles is presented. The findings show that using reflectors with ETSC-HP rises its input energy, storage energy, energy and exergy efficiencies, and reflected and radiation losses but it reduces the convection losses. Using upper, lower and the two reflectors raises the input energy to the collector by about 15.3%, 22.5%, and 37%, respectively, and the output daily storage energy by 14%, 22.1%, and 35.7%, respectively compared with the system without reflectors. The daily thermal efficiency of the ETSC-HP system with upper, lower and the two reflectors is 63.8%, 71.67% and 76.25% compared with 60.57% of the collector without reflectors. Using reflectors with the ETSC-HP raises the system thermal performance curve efficiency by about 16% relative to the collector without reflectors. Moreover, using two reflectors increases the average daily exergy efficiency by about 25.3%. Using reflectors with ETSC-HP proves its ability to raise the energy storage from the collector system compared to previous works.

Research Authors
Saleh Abo-elfadl Ahmed Abd Elrasheed, Hamdy Abo Ali Hassan Ibrahim, Mohammed Fekry Farah El-Dosoky
Research Date
Research Journal
Solar Energy
Research Pages
474-480
Research Publisher
Elsevier
Research Vol
209
Research Website
https://www.sciencedirect.com/science/article/abs/pii/S0038092X20309531
Research Year
2021

Energy, exergy, economic and environmental assessment of double pass V-corrugated-perforated finned solar air heater at different air mass ratios

Research Abstract

An assessment of a flat plate double pass (DP) solar air heater (SAH) having V-corrugated absorber (C_SAH) and corrugated-perforated absorber (CP_SAH) via energy, exergy, economic and environmental approaches (4E) is presented experimentally. The study is performed at four different levels of air mass flow ratios inside the flat plate solar air heater with two levels of absorber plates i.e. C_SAH and CP_SAH. C_SAH and CP_SAH performance is compared with flat SAH (F_SAH) performance. The results show that F_SAH achieves the lowest daily energy efficiency values of 52.5%, 55.86%, 54.77%, and 56.7% while CP_SAH achieves the highest of 67.67%, 69.7%,71.85%, and 70.8% at SP, 1/3 DP, 2/3 DP, and DP conditions, respectively. Moreover, C_SAH and the CP_SAH achieve maximum daily efficiency of 70.58% and 71.85% at 2/3 DP condition. CP_SAH achieves average daily exergy efficiency of 0.78%, 0.89%, 0.97%, and 0.92% with percentage increments of 47%, 55%, 76%, and 54% compared to F_SAH at same previous conditions, respectively. F_SAH at SP condition achieves the maximum energy cost of 0.0427 $/kWh while CP_SAH at 2/3 DP condition achieves the minimum energy cost of 0.0324 $/kWh. The proposed CP_SAH at 2/3 DP condition is the most suitable from the studied cases.

Research Authors
Saleh Abo-elfadl Ahmed Abd Elrasheed,Mohamed S. Yousef, Hamdy Abo Ali Hassan Ibrahim
Research Date
Research Journal
Sustainable Energy Technologies and Assessments
Research Pages
100936
Research Publisher
Elsevier
Research Vol
43
Research Website
https://www.sciencedirect.com/science/article/pii/S2213138820313631
Research Year
2021

Energy, exergy, economic and environmental assessment of using different passive condenser designs of solar distiller

Research Abstract

An assessment of using different passive condenser designs of the solar distiller based on productivity, exergy, energy, energyeconomic, exergyeconomic, enviroeconomic is investigated experimentally. Five different condenser designs are considered; (i) glass plate condenser, GC (CSS), (ii) corrugated aluminum sheet heat sink condenser, CHS, (iii) aluminum heat sink condenser having vertical rectangular fins at its outer surfaces, RHS, (iv) aluminum heat sink condenser having pin fins at its outer surface, PHS, and (v) aluminum heat sink condenser having pin fins at its outer and inner surfaces, DPHS. The findings show that augmenting the rate of condensation by varying the condenser design increases the still yield to a limit and then decreases this yield at a higher condensation rate. CSS has the smallest freshwater yield and still with PHS has the maximum production with an increment of 54 % comparing with GC condenser. The maximum increase of the daily average energy and exergy efficiencies of the still is about 55.3 % and 73.1 %, respectively in case of PHS condenser compared with CSS. Still with DPHS condenser has the maximum production cost while the still with PHS or CHS condenser has the minimum. Distiller with PHS condenser is the best system in achieving CO2 reduction benefits of 1.82 tons CO2/year.

Research Authors
Saleh Abo-elfadl Ahmed Abd Elrasheed,Mohamed S. Yousef, Hamdy Abo Ali Hassan Ibrahim
Research Date
Research Journal
Process Safety and Environmental Protection
Research Pages
302-312
Research Publisher
Elsevier
Research Vol
148
Research Website
https://www.sciencedirect.com/science/article/abs/pii/S0957582020318176
Research Year
2021

Study of the performance of double pass solar air heater of a new designed absorber: An experimental work

Research Abstract

An experimental study on the performance of double pass Solar Air Heater (SAH) having a new designed absorber is performed. The new SAH absorber is constructed from conductive aluminum tubes adjacent to each other and installed in the same direction of the air flowing inside the SAH. The new SAH performance (called Tubular Solar Air Heater (TSAH)) is studied at various mass flow rates of air inside the SAH. Moreover, it is compared with the performance of Flat plate Solar Air Heater (FSAH) having the same dimensions and materials of the TSAH except the absorber design. Findings indicate that the TSAH has higher outlet air temperature, efficiency and net energy gain and lower top heat loss compared to FSAH. TSAH achieves maximum air temperature rise more than 6 °C compared to FSAH at 0.025 kg/s. TSAH efficiency is greater than FSAH efficiency by about 19.4%, 21%, and 40.3%, at inlet air flow rate of 0.075 kg/s, 0.05 kg/s and 0.025 kg/s, respectively. The outlet air temperature and top thermal energy loss of the TSAH decrease with increasing the air mass flow rate, while its efficiency, energy output, and pressure drop increase. Moreover, TSAH efficiency in case of double air pass is greater than single air pass. Despite the TSAH pressure drop is greater than FSAH pressure drop, but its value is very small to impact the TSAH net thermal energy gain. The designed TSAH performance is found greater than the performance of FSAH and previous designs of published SAHs.

Research Authors
Saleh Abo-elfadl Ahmed Abd Elrasheed, Hamdy Abo Ali Hassan Ibrahim, Mohammed Fekry Farah El-Dosoky
Research Date
Research Journal
Solar Energy
Research Pages
479-489
Research Publisher
Elsevier
Research Vol
198
Research Website
https://www.sciencedirect.com/science/article/abs/pii/S0038092X20300980
Research Year
2020

Productivity, exergy, exergoeconomic, and enviroeconomic assessment of hybrid solar distiller using direct salty water heating

Research Abstract

In this work, experimental work is presented on the performance of a hybrid solar distiller comprising solar still (SS) combined with parabolic trough solar collector (PTSC) using direct heating of salty water by the collector. In this technique, the salty water supplied to the SS is heated by passing it directly through the parabolic receiver without using heat transfer mediums that reduce the system efficiency. The study is carried out at different salty water depths inside the SS basin under hot climate conditions of Upper Egypt. The system performance is compared with a previous system using oil as a heat transfer medium between PTSC and still (indirect heating). The advantages of this technique are its ability to reduce initial salty water depth in the basin and avoid using the pumping system and heat exchanger compared to the direct heating. The performance of the proposed system is evaluated based on productivity, energy payback time (EPBT), exergy, enviroeconomic, and exergoeconomic methodologies. Findings illustrate that the present system rises the energy efficiency by about 12%, 27.5%, and 46% and the system exergy efficiency by about 14%, 30%, and 49% at salty water depth 15 mm, 10 mm, and 5 mm in the basin compared with the indirect heating system. Moreover, using this technique of salty water heating reduces the production cost of freshwater by about 71% compared with the direct heating system. The exergoeconomic and enviroeconomic parameters of the direct heating mechanism are more effective compared with those of the indirect heating mechanism.

Research Authors
Hamdy Hassan, Mohamed S. Yousef , Mohamed Fathy
Research Date
Research Journal
Environmental Science and Pollution Research
Research Pages
5482–5494
Research Publisher
Springer
Research Vol
28
Research Year
2020

Investigation of a solar still behaviour using response surface methodology

Research Abstract

This work proposes an innovative statistical model by utilizing the response surface methodology (RSM) method to analyze a batch solar behaviour still. This investigation’s main goal is to study the impact of the input factors (solar radiation, ambient temperature, water depth, and thickness of insulation) most influencing water productivity. The polynomial regression model derived from a numerical balance energy model to predict the solar’s productivity still is established. The quadratic model is checked by a coefficient of determination (R2). An excellent fitting is attained between the forecasted results derived from the statistical model and the numerical simulation derived from the heat balance model. The results reveal that the importance of the influence in the order of impact on the amount of distilled water is water depth, solar radiation, ambient
temperature, and thickness of insulation. A simple polynomial statistical model is stated in this investigation to determine and maximize the amount of distilled water from solar still based on the four considered input factors. 

Research Authors
Oussama Rejeb , Mohamed S. Yousef , Chaouki Ghenai , Hamdy Hassan, Maamar Bettayeb
Research Date
Research Journal
Case Studies in Thermal Engineering
Research Pages
100816
Research Publisher
Elsevier
Research Vol
24
Research Year
2021
Subscribe to