Reliability of multidetector CT in the diagnosis of cerebrospinal fluid rhinorrhea with operative correlation

Research Abstract
Purpose To evaluate the role of non-contrast multidetector CT (MDCT) reliability in localizing CSF leaks and skull base defects in correlation to operative findings. Materials and methods Twenty patients clinically diagnosed to have CSF rhinorrhea; 8 spontaneous and 12 post-traumatic patients were evaluated using 64-rows MDCT with slice section 0.6 mm. CT is considered accurate if correctly determine the site and size of bony defect as matched with operative findings. Results MDCT accurately detected the site of presumed CSF leak in 19 out of 20 cases with sensitivity 95%. Cribriform plate defect is the most common site of defect in 40% of cases with 75% of cases categorized as Keros type II. The consensus image with fair agreement (K = 0.38) shows that coronal reformat has the highest diagnostic performance in 75% of cases while the least diagnostic value is encountered with the axial plane in 15% of cases …
Research Authors
Haisam Atta, Gehan S Seifeldein, Momen AlMamoun, Hisham Imam
Research Department
Research Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Research Member
Research Pages
107-113
Research Publisher
Elsevier
Research Rank
1
Research Vol
48-1
Research Website
https://www.sciencedirect.com/science/article/pii/S0378603X16302340
Research Year
2017